Standard Svensk standard · SS-EN 14511-3:2007

Luftkonditioneringsaggregat, vätskekylare och värmepumpar, med elmotordrivna kompressorer, för rumsuppvärmning och -kylning - Del 3: Testmetoder

Status: Upphävd

· Ersätts av: SS-EN 14511-3:2011 Korrigeras av: SS-EN 14511-3:2007/AC:2008
Köp denna standard

Standard Svensk standard · SS-EN 14511-3:2007

Luftkonditioneringsaggregat, vätskekylare och värmepumpar, med elmotordrivna kompressorer, för rumsuppvärmning och -kylning - Del 3: Testmetoder
Prenumerera på standarden - Läs mer Dölj
Pris: 1 320 SEK
standard ikon pdf

PDF

Pris: 1 320 SEK
standard ikon

Papper

Fler alternativ Färre alternativ
Provläs denna standard
Omfattning
This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling. It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable. This European Standard applies to factory-made units that can be ducted. This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct units are covered by the standard. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser. This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement. This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side. The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard. This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.

Ämnesområden

Luftväxlare, fläktar, luftkonditionering (23.120)


Köp denna standard

Standard Svensk standard · SS-EN 14511-3:2007

Luftkonditioneringsaggregat, vätskekylare och värmepumpar, med elmotordrivna kompressorer, för rumsuppvärmning och -kylning - Del 3: Testmetoder
Prenumerera på standarden - Läs mer Dölj
Pris: 1 320 SEK
standard ikon pdf

PDF

Pris: 1 320 SEK
standard ikon

Papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Värmepumpar, SIS/TK 467

Internationell titel: Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods

Artikelnummer: STD-64255

Utgåva: 2

Fastställd: 2007-12-06

Antal sidor: 52

Ersätter: SS-EN 14511-3/AC:2005 , SS-EN 14511-3:2004

Ersätts av: SS-EN 14511-3:2011